Low and Medium Voltage in Electrical Maintenance – CONFIRMED

ACARA

30 September – 02 Oktober 2019 | Rp 6.900.000 di Hotel Ibis, Yogyakarta – CONFIRMED
14 – 16 Oktober 2019 | Rp 6.900.000 di Hotel Ibis, Yogyakarta – CONFIRMED

Jadwal Training 2019 Selanjutnya …

06 – 08 Januari 2020 | Rp 6.900.000 per peserta di Hotel Ibis Malioboro, Yogyakarta

Jadwal Training 2020 Selanjutnya …

 

 

Low and Medium Voltage Training Description

The backbone of many electric power systems is the medium voltage distribution system. Typically operating at voltages ranging from 2,400 to 34,500 Volts, voltage stress, corona, surges and protection of equipment all create unique challenges in design, equipment selection, operation and engineering. This 2 day class takes you through the basics of medium voltage power systems including components,equipment, design and operation problems as well as protection of medium voltage systems.

 

Low and Medium Voltage Training Purpose

Setelah selesai mengikuti kursus Electrical Maintenance Low and Medium Voltage ini, peserta diharapkan akan mengerti dan memahami masalah Audit sampai pada penerapan konsep Power Management System. Dimana hal itu diperlukan oleh perusahaan sebagai suatu komponen pendukung kegiatan produksi untuk menjamin ketersediaan energi listrik dengan efisien dan murah.

 

Low and Medium Voltage Training Outline

MEDIUM VOLTAGE SAFETY

  • Electrocution at Low vs. Medium Voltage, Arc Flash,
  • Qualified Person, Approach Boundaries

TYPES OF MEDIUM VOLTAGE SYSTEMS

  • Utility and Industrial One lines, Reliability Requirements,
  • Overhead and Underground Systems, Regulated Systems

MEDIUM VOLTAGE CABLE

  • Copper vs. Aluminum Design, Voltage Ratings
  • Insulation Ratings, 100%, 133%, 173% Insulation Levels,
  • Shielding Requirements, Electric Fields, Terminating MV
  • Conductors, Orientation of Overhead Lines

MEDIUM VOLTAGE SUBSTATION TRANSFORMERS

  • Core and Coil Design, Aluminum and Copper Windings
  • Tank Construction, Loss Evaluation, Efficiency, Regulation

SPOT NETWORKS

  • Spot Network Design, Network Protectors, Network Protector
  • Relay Operation, Directional Protection Requirements

PARTIAL DISCHARGE

  • Corona, Surface Tracking, Voltage Stress, Sensing Partial
  • Discharge, Component Failure

GROUNDING MEDIUM VOLTAGE SYSTEMS

  • Resistance Grounding, Solid Grounding, Ungrounded Delta
  • Charging Current, Effect of Ground Faults on Delta Voltage

SURGE PROTECTION

  • Lightning and Switching Surges, Classes of Surge Arresters
  • MCOV Ratings – (Maximum Continuous Operating Voltage)
  • TOV – (Maximum Temporary Over Voltage Capability),
  • Protective Characteristics, Surge Arrester Selection, Energy
  • Capability, Effect of Grounding on Arrestor Selection,
  • Insulation Coordination,

CURRENT TRANSFORMER APPLICATIONS

  • Ratings, Selection Process, Accuracy, Saturation, Excitation
  • Curves, Burden Calculation, Momentary Ratings

MEDIUM VOLTAGE CIRCUIT BREAKERS

  • Vacuum, Air, Oil, SF6 Designs, Symmetrical Interrupting
  • Rating, K-Rated Voltage Factor, Close and Latch Capability

RECLOSERS

  • Application on Feeder Circuits, Recloser Settings
  • Continuous Current and Interrupting Ratings

MEDIUM VOLTAGE FUSES

  • Medium Voltage Switches, Load Rating, Close and Latch
  • Rating, Short Time Rating, Expulsion vs. Current Limiting
  • Fuse Characteristics, E and R Rated Fuses, Fuse Cutouts

MEDIUM VOLTAGE PROTECTION CONCEPTS

  • Medium Voltage Protection, Relays, Circuit Breakers, R and
  • E rated Fuses, Short Circuit vs. Overcurrent Protection

DISTRIBUTION FEEDER PROTECTION

  • Protection with Fuses – 300%, Overcurrent Protection with
  • Relays – 600%, Short Circuit Damage Characteristics, Relay
  • “Reach” for End of Line Faults

ROTATING MACHINERY PROTECTION

  • Requirements, Decrement Curves, Thermal Damage Curves,
  • Reactive, Capability Curves, Differential Protection

MEDIUM VOLTAGE MOTOR CONTROLLERS

  • Protection Requirements, Motor Management Relays, Circuit
  • Breaker Protection, Relaying, Class R Rated Fuses

TRANSFORMER PROTECTION

  • ANSI C57 Thru Fault Curves, Impact of Transformer Winding
  • Configuration, Overview of Differential Protection, Inrush and
  • Harmonic Restraint

 

Training Audience

  • D3 atau SLTA yang berpengalaman kerja minimal 3 tahun, dan atau setara.
  • Teknisi, Operator dan Supervisor didalam bidang  instrumentasi, maintenance dan operasional.
  • Mereka yang dalam tugasnya berhubungan dan atau terkait dengan materi kursus.

 

Training Methods

Presentasi, diskusi, dan studi kasus

 

Jadwal Training 2019

Hotel Ibis Malioboro, Yogyakarta

  • 30 September – 02 Oktober 2019
  • 07 – 09 Oktober 2019
  • 14 – 16 Oktober 2019
  • 21 – 23 Oktober 2019
  • 28 – 30 Oktober 2019
  • 04 – 06 November 2019
  • 11 – 13 November 2019
  • 18 – 20 November 2019
  • 25 – 27 November 2019
  • 02 -04 Desember 2019
  • 9 – 11 Desember 2019
  • 16 – 18 Desember 2019
  • 23 – 24 Desember 2019
  • 30 – 31 Desember 2019

 

Jadwal Training 2020

Hotel Ibis Malioboro, Yogyakarta

  • 6 – 8 Januari 2020
  • 13 – 15 Januari 2020
  • 20 – 22 Januari 2020
  • 27 – 29 Januari 2020
  • 3- 5 Februari 2020
  • 10 – 12 Februari 2020
  • 17 – 19 Februari 2020
  • 26 – 28 Februari 2020
  • 2 – 4 Maret 2020
  • 9 – 11 Maret 2020
  • 16 – 18 Maret 2020
  • 23 – 24 Maret 2020
  • 30 Maret 2020 – 1 April 2020
  • 6 – 8 April 2020
  • 13 – 15 April 2020
  • 20 – 22 April 2020
  • 27 – 29 April 2020
  • 4 – 6 Mei 2020
  • 11 – 13 Mei 2020
  • 2 – 4 Juni 2020
  • 8 – 10 Juni 2020
  • 15 – 17 Juni 2020
  • 22 – 24 Juni 2020
  • 29 Juni 2020 – 1 Juli 2020
  • 6 – 8 Juli 2020
  • 13 – 15 Juli 2020
  • 20 – 22 Juli 2020
  • 27 – 29 Juli 2020
  • 3 – 5 Agustus 2020
  • 10 – 12 Agustus 2020
  • 18 – 19 Agustus 2020
  • 24 – 26 Agustus 2020
  • 31 Agustus 2020 – 2 September 2020
  • 7 – 9 September 2020
  • 14 – 16 September 2020
  • 21 – 23 September 2020
  • 28 – 30 September 2020
  • 5 – 7 Oktober 2020
  • 12 – 14 Oktober 2020
  • 19 – 21 Oktober 2020
  • 26 – 28 Oktober 2020
  • 2 – 4 November 2020
  • 9 – 11 November 2020
  • 16 – 18 November 2020
  • 23 – 25 November 2020
  • 30 November 2020 – 2 Desember 2020
  • 7 – 9 Desember 2020
  • 14 – 16 Desember 2020
  • 21 – 23 Desember 2020
  • 28 – 30 Desember 2020

 

Training Investation & Facilities

  • Rp 6.900.000 (Non Residential, Belum Termasuk Pajak PPn 10%)
  • VIP training Rp 8.9000 (4 Hari , Non Residential dengan tambahan Fasilitas Paket studi lapangan/ City tour dan Belum Termasuk Pajak PPn 10%)
  • Quota minimum 2 peserta
  • Fasilitas : Certificate,Training kits, USB,Lunch,Coffe Break, Souvenir
  • Untuk peserta luar kota disediakan transportasi antar-jemput dari Bandara/Stasiun ke Hotel khusus bagi perusahaan yang mengirimkan minimal 3 orang peserta)

 

Low and Medium Voltage Training Instructor

Tugino, ST.,MT dan Tim

Having knowledge and experience as practician and trainer in Electricity Maintenance.

Training Electrical Maintenance Low and Medium Voltage

Formulir Pra-Pendaftaran Public Training / Permintaan Informasi Lebih Lanjut
  1. JENIS INFORMASI/TRAINING
  2. (required)
  3. (required)
  4. DATA PRIBADI
  5. (required)
  6. (required)
  7. (required)
  8. (valid email required)
  9. (required)
  10. (required)
  11. DATA PRE REGISTRATION (Tidak Mengikat)
  12. (required)
  13. PESAN UNTUK PENYELENGGARA TRAINING
  14. Captcha
 

cforms contact form by delicious:days

Leave a Reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.