ELECTRICAL EQUIPMENT IN POWER PLANT

ACARA

17 – 19 September 2018 | Rp 6.900.000,- per peserta di Hotel Ibis, Yogyakarta
24 – 26 September 2018 | Rp 6.900.000,- per peserta  di Hotel Ibis, Yogyakarta
01 – 03 Oktober 2018 | Rp 6.900.000,- per peserta  di Hotel Ibis, Yogyakarta

Jadwal Training 2018 Selanjutnya …

02 – 04 Januari 2019 | Rp 6.900.000,- per peserta di Hotel Ibis, Yogyakarta
07 – 09 Januari 2019 | Rp 6.900.000,- per peserta di Hotel Ibis, Yogyakarta

Jadwal Training 2019 Selanjutnya …

 

 

ELECTRICAL EQUIPMENT IN POWER PLANT TRAINING DESCRIPTION

This course gives the understanding operation and protection of Electrical Equipment especially in Power Plant of Geothermal and Steam turbine generation.

The main electrical equipment for the above plant are Synchronous generator, Switchgear covering SF6 and Vacuum Power Circuit Breakers, Oil Power Transformer, Transmision and Distribution Conductor, Electric motors, and also Protective Relays. The purpose of this course is to develop a thorough understanding of those electrical equipment.

Discuss safe and proper operation and protection of critical components and application, operation, inspection and testing issues with an overriding emphasis on safety. Case studies covering the main manufacturer’s equipment will illustrate the important practical principles. Other power system protection components will be discussed as well to ensure that main electrical equipment in power plant is understood in the correct context.

 

ELECTRICAL EQUIPMENT IN POWER PLANT TRAINING OBJECTIVE

Participants will strongly learn about the following :

  1. Operation and protection of Power Generator, Switchgear, Oil Power Transformer, and Transmission and Distribution Conductors, Protective Relays.
  2. Inspection and testing of the main electrical equipment

 

ELECTRICAL EQUIPMENT IN POWER PLANT TRAINING CONTENTS

  1. ELECTRICAL POWER GENERATION SYSTEMS
    • Understanding of electrical power generation systems
  2. PLANT ELECTRICAL EQUIPMENT
    • Classification selection and type determination of plant electrical equipment
  3. SAFETY POLICIES
    • General safety precautions and the use of personal protective equipment
    • Principles of safety rules, Principles of personnel authorisation
    • Operative training for safe operation of switchgear
    • Isolation in a circuit breaker context
    • Safety documentation
    • Operational and safety locking, caution and danger notices
    • Safe working in electrical equipment environment
  4. POWER GENERATOR OPERATION AND PROTECTION
    • Electrical generation, Frequency, construction,
    • Exciter, brushless exciter, PMG, Voltage regulation, load on generator
    • Protection device 32, 40, 46, 51V, 51GN, 87G, 87 GG, 60, 59, and 86.
    • Relay Coordination, Logic Diagram.
  5. SWITCHGEAR – ORIGINS & TYPES
    • Single line diagrams, Active and passive network components, Circuit breaker utilisation
    • Alternative forms of MV switchgear – ring main units, load breaking/fault making switches, Fuse switches, HV fuses in combination with, and as alternative to circuit breakers
    • Switchgear in association with disconnectors, Fixed and withdrawable designs, Switchgear standards, Factors affecting switchgear selection
  6. OIL POWER TRANSFORMER
    • Construction, Vector Group
    • Buchloz Protection Relay, Jansen, Sudden Pressure Relay, Neutral Grounding Resistor, Power Transformer Protective Relay.
  7. TRANSMISSION AND DISTRIBUTION CONDUCTORS
    • Nomenclature, cable terminilogy, construction, reference standards
    • Single core copper and aluminium power cables, three single core underground or overhead twisted cables, overhead transmission lines.
  8. ELECTRIC MOTOR OPERATION AND PROTECTION
    • Speed, Torque, Power and their relationship
    • Construction, losses and efficiency, rotattion
    • Characteristic, Starting, Dahlander
    • Motor Protective relays
  9. POWER CIRCUIT BREAKERS & FUSES
    • Main function of Circuit Breaker and Fuse
    • Air CB, Oil CB, Vacuum CB, and SF6 CB
    • Closing and Opening operation of Circuit Breaker
    • Testing procedures, interaction with protective relays
    • Fuse Switch, reclosing
  10. INSTRUMNENT TRANSFORMERS
    • Current Transformer and its inspection and testing procedures
    • Potetntial Transformer and how to test and inspect
  11. MAIN AND BACK UP PROTECTION AND COORDINATION
    • Main Protection in package
    • Back up protection in package
    • Relay coordination

 

ELECTRICAL EQUIPMENT IN POWER PLANT TRAINING METHODS

  • Presentasi
  • Diskusi dan Sharing Pengalaman

 

Jadwal Training 2018

Hotel Ibis Malioboro ,Yogjakarta

  • 17 – 19 September 2018
  • 24 – 26 September 2018
  • 01 – 03 Oktober 2018
  • 08 – 10 Oktober 2018
  • 15 – 17 Oktober 2018
  • 22 – 24 Oktober 2018
  • 29 – 31 Oktober 2018
  • 05 – 07 November 2018
  • 12 – 14 November 2018
  • 21 – 23 November 2018
  • 26 – 28 November 2018
  • 03 – 05 Desember 2018
  • 10 – 12 Desember 2018
  • 17 – 19 Desember 2018
  • 26 – 28 Desember 2018

 

Jadwal Training 2019

Hotel Ibis Malioboro, Yogykarta

  • 2 – 4 Januari 2019
  • 7 – 9 Januari 2019
  • 14 – 16 Januari 2019
  • 21 – 23 Januari 2019
  • 28 – 30 Januari 2019
  • 6 – 8 Februari 2019
  • 11 – 13 Februari 2019
  • 18 – 20 Februari 2019
  • 25 – 27 Februari 2019
  • 4 – 6 Maret 2019
  • 11 – 13 Maret 2019
  • 18 – 20 Maret 2019
  • 25 – 27 Maret 2019
  • 1 – 2 April 2019
  • 8 – 10 April 2019
  • 15 – 17 April 2019
  • 22- 24 April 2019
  • 29 – 30 Mei 2019
  • 6 – 8 Mei 2019
  • 13 – 15 Mei 2019
  • 20 – 22 Mei 2019
  • 27 – 29 Mei 2019
  • 10 – 12 Juni 2019
  • 17 – 19 Juni 2019
  • 24 – 26 Juni 2019
  • 1 – 3 Juli 2019
  • 8 – 10 Juli 2019
  • 15 – 17 Juli 2019
  • 22 -24 Juli 2019
  • 29 – 31 Juli 2019
  • 5 – 7 Agustus 2019
  • 13-15 Agustus 2019
  • 19 – 21 Agustus 2019
  • 26 -28 Agustus 2019
  • 02 – 04 September 2019
  • 09-11 September 2019
  • 16 – 18 September 2019
  • 23 – 25 September 2019
  • 30 September – 02 Oktober 2019
  • 07 – 09 Oktober 2019
  • 14 – 16 Oktober 2019
  • 21 – 23 Oktober 2019
  • 28 – 30 Oktober 2019
  • 04 – 06 November 2019
  • 11 – 13 November 2019
  • 18 – 20 November 2019
  • 25 – 27 November 2019
  • 02 -04 Desember 2019
  • 9 – 11 Desember 2019
  • 16 – 18 Desember 2019
  • 23 – 24 Desember 2019
  • 30 – 31 Desember 2019

 

ELECTRICAL EQUIPMENT IN POWER PLANT TRAINING INVESTATION & FACILITIES

  • 6.900.000 (Non Residential, Belum Termasuk Pajak PPn 10%)
  • Quota minimum 2 peserta
  • Fasilitas : Certificate,Training kits, USB,Lunch,Coffe Break, Souvenir
  • Untuk peserta luar kota disediakan transportasi antar-jemput dari Bandara/Stasiun ke Hotel khusus bagi perusahaan yang mengirimkan minimal 3 orang peserta)

 

ELECTRICAL EQUIPMENT IN POWER PLANT TRAINING INSTRUCTOR

Mursid Sabdullah ST MT  and Team

OPERATION & PROTECTION FOR ELECTRICAL EQUIPMENT IN POWER PLANT

Formulir Pra-Pendaftaran Public Training / Permintaan Informasi Lebih Lanjut
  1. JENIS INFORMASI/TRAINING
  2. (required)
  3. (required)
  4. DATA PRIBADI
  5. (required)
  6. (required)
  7. (required)
  8. (valid email required)
  9. (required)
  10. (required)
  11. DATA PRE REGISTRATION (Tidak Mengikat)
  12. (required)
  13. PESAN UNTUK PENYELENGGARA TRAINING
 

cforms contact form by delicious:days

Leave a Reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.